Product Overview:
The 30W LED Emergency Backup Driver offers a reliable emergency power solution for LED fixtures, providing up to 90 minutes of backup power during outages. It requires access to the existing LED driver with an output voltage range between 156-260Vdc, and the LED fixture must have a wattage higher than 30W. Designed to support 100-277V AC input, this driver ensures seamless functionality for your LED lighting systems.
Key Features:
- Constant Power Output: Provides consistent 30W emergency power supply.
- Field Installable Split Kit: Easily add emergency backup functionality to an existing LED fixture.
- Wide Application: Ideal for linear lights, low/mid bay lighting, ETC.
- 1000 Charge Cycles: Ensures long-lasting performance with a durable battery capable of up to 1000 charge cycles.
- Certifications: Compliant with UL 924, CSA C22.2, FCC, IP44, and CA Title 20 standards, guaranteeing safety, energy saving, and quality.
- Backed by a 5-year warranty for peace of mind.
Luminaire Lumen Output Guideline During Emergency Operation:
- Determine the fixture efficacy under normal AC operation, typically provided by the luminaire vendor.
- Multiply the luminaire’s LM/W (lumen per watt) by the rated emergency output power (20W for this driver).
- Example: A Konlite High Bay Light (KAT300MCLV4F) with 160 LM/W under normal conditions is providing a lumen output of 4,800 lumens during emergency operation (30W x 160 LM/W).
This backup driver is perfect for a range of commercial and industrial applications where emergency lighting is essential. For technical details, including wiring diagrams, check the Downloads section.
Applications
•Security Lights | •Workshops |
•Convention Centers | •Low Bays and Mid Bays |
•Storage Facilities | •Distribution Centers |
•Factories | •Supermarkets |
•Retail | •Loading Areas |
Specifications
Brand | Konlite | MPN | EMB30YY-ZZZ |
Warranty | 5 Years | UPC | 659675300597 |
Input Voltage | 100-277V | Max Input Current | 50mA @120V, 35mA @240V, and 30mA @277V |
Input Wattage | 7W | Inrush Current | 3A |
Turn-on Delay Time | < 2s | Power Factor | > 0.9 under 120~277Vac input |
Output Voltage | 156-260Vdc | Emergency Power | 30W (constant) |
Surge Protection | 3kV | Output Current | 1500mA @ 20Vdc, 518mA @ 58Vdc |
Outer Voltage Protection | Yes | Outer Power Protection | Yes |
Emergency Operation | 90 Minutes | Recharge Time | 24 Hours |
Battery Type | Li-Ion | Battery Capacity | 14.4V 5000mA |
Operating Temperature | 32ºF to 122ºF | Storage temperature | − 4ºF to 131ºF |
Max Case Temperature | 167ºF | Storage Humidity | ≤65% |
Unit Dimensions | Driver: 7.32" *1.5"*0.99" Battery: 0.99"* 1.63" * 1.74" | Unit Weight | 1 lbs |